On this page, you'll find out what you should do if you see a hazard or emergency involving overhead power lines or pylons. You'll also find out more about what is safe and not safe to do near overhead power lines and underground cables.
Our networks cross areas of land, in towns, cities and in the countryside, that are mostly owned and occupied by third parties. The areas of land surrounding our equipment are constantly subject to change and development.
If you spot a potential hazard on or near an overhead electricity line please call the 24-hour electricity emergency helpline :
Follow these steps:
do not approach any hazard, even at ground level - keep as far away as possible
Download our Fire and Rescue Guidance document to find out more.
Download nowPlease click on the relevant topic below for more advice and information.
If any changes in ground levels that are proposed in the vicinity of the overhead line might reduce safety clearances, please contact us first.
Safety advice for overhead lines:
It's dangerous to climb on top of high vehicles parked or passing under overhead electricity wires.
No plant, machinery, scaffolding, or personnel should encroach within the safety zone of overhead conductor lines.
Take care when moving ladders, elevators, irrigation pipes or other long objects. They should be moved only when horizontal or in their lowest position.
Never reduce the clearance under overhead electricity lines by dumping or tipping waste material, erecting structures, buildings or hay stacks, or creating storage areas under lines.
No plant, machinery, scaffolding, or personnel should encroach within the safety zone of the overhead conductor lines.
Take care when moving ladders, elevators, irrigation pipes or other long objects. They should be moved only when horizontal or in their lowest position.
Never reduce the clearance under overhead electricity lines by dumping or tipping waste material. erecting structures, buildings or hay stacks, or creating storage areas under lines.
Overhead electricity lines are normally bare (uninsulated) and if an object gets too close it is possible that a ‘flashover’ can occur, where electricity will jump over a distance to reach earth via the object. Flashovers can kill or cause severe shocks and burns to any person nearby.
In order to prevent flashover there are minimum safety clearances between overhead lines and the ground, roads, or objects on which a person can stand.
A flashover to a tree can cause a loss of supply to customers, a fire in the tree, or can lead to the tree itself conducting electricity.
Despite the dangers, we cannot actually prevent trees and vegetation being planted beneath our overhead electricity lines, as we do not own the land.
We have a duty to make sure that no tree comes close enough to an overhead electricity line to cause a flashover.
We employ specialist contractors to undertake vegetation management beneath our overhead electricity lines to make sure safety clearances are not infringed over a number of growing seasons.
All vegetation clearance work beneath and adjacent to overhead electricity lines must be carried out by specially trained staff.
Only low height, slow growing species should be planted beneath overhead electricity lines, conductors, and towers.
If you are proposing planting in the area around a pylon (tower) base, you should consider the need to maintain safe vehicle access to the tower base for overhead line maintenance activities, and to prevent unauthorised access to towers.
Tree roots can disturb and prevent access to maintain underground electricity cables. Our prescribed planting distances between trees and buried services must be observed.
Please contact us for detailed technical advice before you finalise any landscape scheme.
Safety advice for leisure activities near overhead lines:
Large birds, such as swans and geese, sometimes collide with overhead line conductors in poor visibility, resulting in their injury or death.
Where bird collision has been identified as a problem, sometimes line-marking devices can be fitted to increase a line’s visibility.
Overhead line towers are sometimes used by birds as convenient structures for roosting, often in significant numbers.
Where bird fouling is a problem a number of methods to dissuade birds from roosting on towers may be used. The effectiveness of the bird scaring is monitored in conjunction with grantors and wayleave officers.
High-voltage overhead lines and certain items of substation equipment can generate noise. With lines, the level of this noise depends on the voltage. Sometimes a ‘crackling’ sound accompanied by a low-frequency hum can be heard.
Noise from an overhead power line is produced by a phenomenon known as ‘corona discharge’. Overhead lines are built to minimise this, but surface irregularities caused by damage, insects, raindrops or pollution may locally enhance the electric field strength sufficient for corona discharges to occur.
The noise levels associated with an overhead power line are weather-related and higher noise levels are likely to occur during:
Where complaints about noise arise, we will investigate the cause of the noise and, if our equipment or practices are at fault, do all that we reasonably can to minimise the noise level.
We also research lower noise alternatives that can be used when installing or refurbishing equipment. Where practical, we will deploy new techniques or equipment that produce less noise.
All our employees and contractors carry identification. Ask to see their identification if you are unsure about people visiting your land.
Don’t assume that delivery drivers and contractors know, or have remembered the route of, overhead electricity lines. Remind them – it could save their lives.
If you’re experiencing a power cut, you should call 105. Do not call your electricity supplier. Electricity suppliers sell consumers energy and are not responsible for power lines. Calling 105 is a free service.
When you call 105 you’ll be put through to your distribution network operator. Or you can find out which one is yours by visiting this page.